Ducted heat pump air handler installed in a crawlspace

Residential · Berkeley, CA · 2026

Neilson St, Berkeley: gas furnace to a 3-ton Mitsubishi ducted heat pump

A Berkeley home off gas: the old furnace came out and a 3-ton Mitsubishi ducted heat pump went in on the existing ducts, with old asbestos duct sections abated and replaced and MERV-13 filtration at the return.

This Berkeley house was heated by a gas furnace on a duct system that was mostly worth keeping. We pulled the furnace and installed a 3-ton Mitsubishi ducted inverter heat pump in its place, so the house now heats and cools through the same registers. Accessible sections of the old ductwork were replaced, with asbestos abatement where we found it, and a Honeywell MERV-13 media filter went in at the return so the new system moves cleaner air from day one.

Type
Heat Pump Conversion
Client
Residential homeowner
System
Mitsubishi 3-ton ducted heat pump (SVZ-AP36NL / SUZ-AA36NL) on the existing ductwork
Location
Berkeley, CA · 2026

Scope

  • — Removed and disposed of the existing gas furnace
  • — Mitsubishi SVZ-AP36NL ducted air handler matched to an SUZ-AA36NL outdoor unit (3 tons)
  • — Tied into the existing duct system for air distribution
  • — Replaced accessible existing ductwork, with asbestos abatement where present; joints sealed and secured
  • — Refrigerant line set, condensate drain and control wiring
  • — New electrical circuits from the main panel to the outdoor unit and air handler, with disconnects
  • — Honeywell F200 MERV-13 media air cleaner at the return
  • — Mitsubishi kumo touch (MHK2) thermostat
  • — Nitrogen pressure test, evacuation, charge per manufacturer specs
  • — Permits, startup, airflow check and commissioning

Constraints

  • — Older ductwork with asbestos-containing sections
  • — Keeping the existing duct layout and registers
  • — Occupied home

3rdGen's Role

3rdGen specified the system, pulled the permits, removed the furnace, handled the duct replacement and abatement scope, installed and commissioned the heat pump.

Outcome

No more gas furnace. The house heats and cools on one quiet inverter heat pump through its original registers, with MERV-13 filtration on the return.

Photography

Related Capabilities

Mitsubishi SVZ-AP / SUZ-AA ducted heat pump kumo touch MHK2 thermostat Honeywell F200 MERV-13 media filter Gas furnace to heat pump conversion Duct replacement and asbestos abatement coordination Filtration upgrades Berkeley Heat Pump Conversion

Project Inquiry

Tell Us What You’re Planning

Home or building — pick your project type, ZIP, and timeline, then leave your contact info. We’ll review it and follow up.

We design and install complete systems in the East Bay, San Francisco and Marin. We do not do repair, service calls or maintenance.

Project category
Project type
Timeline