Residential HVAC · Tiburon, CA

Residential HVAC & Heat Pumps in Tiburon, CA

Zoned heat pump systems for Tiburon houses with big glass, multiple levels and little room to hide a duct. We calculate the loads, then find the quietest, least visible way to deliver the air.

Remodels · Retrofits · Heat Pumps · Multi-Zone Systems

Project Inquiry

Plan your Tiburon project

Share your project type, ZIP, timeline, and how to reach you. We will follow up.

We design and install complete systems in the East Bay, San Francisco and Marin. We do not do repair, service calls or maintenance.

  • 5.0 Google Rating 5.0 out of 5 stars
  • Mitsubishi Electric Diamond Contractor
  • C-20 + C-36 Licensed & Bonded
  • Serving the Bay Area since 2015

A published multi-zone project

Whole-home heat pump remodel

View project →
Mitsubishi wall unit in a Berkeley remodel by 3rdGen
Mitsubishi wall unit in a Berkeley remodel by 3rdGen
Mitsubishi hanging outdoor units in a Berkeley remodel by 3rdGen

High-end residential remodel

Hearst Remodel

A Berkeley remodel with six indoor heads and two outdoor units, shown here to illustrate how we handle zoning and finish-sensitive routing on homes like Tiburon’s.

Home type
Existing home, remodel for sale
System
Fujitsu multi-zone ductless heat pump
Mechanical scope
  • · Six indoor wall units
  • · Two outdoor units
  • · Wall-mounted outdoor brackets
  • · Refrigerant routing and field coordination

Challenge

  • Existing older home with limited equipment placement options
  • Outdoor units required side-yard wall bracket mounting
  • Finish-sensitive interior installation
  • Coordination with the general contractor’s remodel schedule

3RDGEN scope

  • Six-zone ductless heat pump installation
  • GC-led remodel coordination
  • Permit and inspection support
  • Startup as part of the completed remodel scope

Outcome

The six-zone Fujitsu ductless system was installed, permitted, inspected, and completed as part of the home’s remodel-for-sale scope — delivering zoned heating and cooling without a conventional ducted retrofit.

Representative example from a Berkeley, CA remodel, not a project in this city. Photos and full details on the project page.

View project

Local projects

Heat pump & HVAC installs for Tiburon homes

Recent installs by the 3rdGen crew that serves Tiburon: ducted and ductless heat pumps, air handlers and ductwork.

Residential outdoor condenser unit on a pad beside a stucco wall with landscaping
White ductless heat pump outdoor unit mounted on steel rails on a roof deck
Large two-fan heat pump outdoor condenser standing on a pad beside a house
White heat pump outdoor unit installed against a wall
Ductless heat pump condenser mounted on a pad beside a gray house with a neat line set
Air handler in an attic with insulated flex duct and a neat white condensate drain

Glass, slope and sight lines

A Tiburon house with a view needs HVAC designed around the view

Window walls pull sun into a room and push cooling loads up. They also remove the wall space where wall units would go. The system has to deliver comfort without a grille on every sightline.

We split each house by wing and level, calculate each load, and then choose between ducted zones, ductless heads and a mix. The right answer is different for a mid-century with vaulted ceilings than for a recent custom build.

The Town’s guidance treats hillside areas as most of Tiburon and notes that exterior items may need separate design review. We locate outdoor units and screening with that in mind.

  • Multiple levels

    Heat rises and sun hits unevenly. Zoning by floor and wing keeps comfort even.

  • Vaulted ceilings

    No attic means we look for chases in closets, floors and soffits, or use ceiling cassettes in secondary rooms.

  • Hillside pads

    Outdoor units on slopes need level mounting, drainage and a service path.

  • Quiet operation

    Homes sit close on many Tiburon streets, so we pick low-sound inverter units and set them away from bedrooms.

HVAC design in Tiburon

Tiburon heat pump projects start with the view, the slope and the ceiling cavity

Tiburon has a lot of hillside homes with big glass and a long list of things the owner does not want to see: wall units, loud condensers, soffits. The mechanical design has to respect all of that and still deliver even comfort. We begin with the loads, then work out where air and refrigerant can travel.

Design climate · Title 24 Climate Zone 3
Winter design temp
36°F
Summer design temp
77°F

Design temperatures for Tiburon are about 36°F heating and 77°F cooling. Bay breezes keep the peaks mild, so tonnage tends to stay small even in large houses. The glass is what pushes cooling loads up, especially on west and south exposures with views.

ACCA Manual J design data · Tiburon (ACCA micro-climate)

Typical Tiburon construction

Many Tiburon houses are wood-frame homes on sloped lots, with a main living level above a lower level or garage. Mid-century homes with vaulted ceilings and exposed beams are common, and they leave very little place to hide a duct.

Larger custom homes and recent remodels usually have multiple levels, several bedroom wings and separate living zones that do not want the same temperature at the same hour.

Hillside lots also limit outdoor unit locations. Retaining walls, setbacks and neighbors a few feet away all affect where a condenser can sit.

Zoning beats one big system

A single thermostat on a multi-level house with a glass wall tends to overcool one end and underheat the other. We compare multiple ducted zones against a multi-zone ductless layout and a hybrid, based on each wing’s own Manual J load.

Vaulted ceilings and exposed beams

When there is no attic and no soffit, we look at slim concealed fan coils in closets, below-floor runs, or ceiling cassettes in secondary rooms. The Manual D work is mostly about finding any legitimate duct path.

Equipment selection for big glass

Manual S matters most here. We check sensible and latent capacity at design conditions so an oversized unit does not short cycle on mild days.

Sound and sight lines

On tightly spaced hillside lots, outdoor unit noise and visibility are part of the design. We choose quiet inverter condensers and place them with sound, screening and service access in mind.

  • Multi-zone heat pump design

    Separate zones for bedroom wings, living areas and lower levels, each sized to its own load.

    Heat pump installation →
  • Whole-house system replacement

    Replace old furnaces and split AC with a heat pump system, with ducts, controls and electrical scoped together.

    Replacement & conversion →
  • HVAC for architect-led remodels

    We join the design team to settle equipment rooms, chases and ceiling space before drawings are final.

    HVAC for remodels →
  • HVAC for new construction

    Rough-in layouts, load calculations and equipment plans for rebuilds and ground-up homes.

    HVAC for new construction →
  • Manual J, S and D documentation

    Complete load, equipment and duct reports for your design team or the town building division.

    Manual J load calculations →
  • Mitsubishi Diamond Contractor installation

    Factory-trained installation and extended warranty options on qualifying Mitsubishi systems.

    Diamond Contractor →

Tiburon permits, power and incentives

The Town of Tiburon issues mechanical permits through its Building Division. Where an outdoor unit or screening changes the exterior, separate design review may apply, so we flag the equipment location up front and prepare the load report and equipment submittals the permit file needs.

MCE is the default electricity generation provider in Tiburon, with PG&E delivering the power. Heat pump incentives from TECH Clean California, BayREN and the utilities come and go, so we confirm what is available when we price the job rather than quote amounts.

Where we work around Tiburon

Across the Tiburon peninsula from Old Tiburon to the ridge streets, and in neighboring Belvedere, Strawberry and Mill Valley.

Homeowner reviews

Trusted by Bay Area Homeowners

5.0
5 out of 5 stars from 207 Google reviews

207 Google reviews

  • Mitsubishi Electric outdoor heat pump installed on a concrete pad at a Bay Area home Expand
    Mitsubishi mini-split installed with outstanding care. Indoor and outdoor units done right. High efficiency meant a meaningful federal tax credit too.
    Gary Marks Google review
  • Mitsubishi Electric Smart Multi outdoor unit wall-mounted on a residential exterior Expand
    Devin and his crew did a fantastic job installing AC for our whole house. High quality Mitsubishi equipment and a clean installation throughout.
    Christian Vuerings Google review
  • Mitsubishi Electric air handler installed in an insulated attic with sealed duct connections Expand
    Devin is meticulous, methodical, and knowledgeable. Professional crew and a heat pump install we trust completely.
    D C Google review

Photos from the installs above

Read all 207 reviews

Our process

How we work through a Tiburon project

Bigger houses mean more zones and more coordination. The steps below keep the design on paper matching the house you end up with.

01 — Walkthrough and plans

We review drawings if you have them, tour the house level by level and note glass, ceilings and any planned work.

02 — Manual J by zone

Heating and cooling loads calculated per room and rolled into zones, using real window and insulation data.

03 — Manual S and D

Equipment selected to the load, with duct and line set layouts drawn to fit the available cavities.

04 — Permit and design review

Mechanical permit through the Town, and outdoor unit information ready for any design review that applies.

05 — Rough-in and set

Ducts and lines go in before finishes close, then equipment is set and connected.

06 — Zone commissioning

Each zone is balanced and tested, and controls are explained before handoff.

Design and install as one

A Tiburon project, from first sketch to commissioning

Because the design and the installation come from the same team, the ceiling cavity we planned on paper is the one we actually build in.

We commission every system and give you a clear control walkthrough.

Tell us about the project
  • Design review

    Loads, zones and equipment locations agreed with you and your design team.

  • Rough-in

    Ducts, line sets and electrical placed before ceilings and finishes close up.

  • Equipment set

    Indoor and outdoor units installed with screening, pads and condensate handled.

  • Startup

    Airflow, refrigerant charge and zone controls tested and documented.

Cost

What moves the price on a Tiburon heat pump project

Tiburon quotes vary more by house than by brand. Number of zones, ducted versus concealed layouts, how many floors the lines must cross, slope access for the outdoor units, and coordination with a larger remodel are the biggest drivers.

Ducted heat pump, existing ducts usable $20k–$30k Equipment tier, capacity, controls, condenser location and access
Ducted heat pump + duct repair or resizing $25k–$45k Amount of ductwork replaced, crawlspace or attic access, return-air changes
Ductless multi-zone, 3–4 heads $25k–$40k Head type, line-set length, routing, concealment and finish conditions
Whole-home ducted + ductless combination $40k–$80k+ Multiple systems, zoning, ductwork, filtration, ventilation and architectural coordination
New construction system $20k–$50k+ Building size, system count, Title 24/design requirements and coordination with the build
ADU system $10k–$15k Zone count, head type, line-set routing, and whether the ADU shares the main house or stands alone
Electrical panel upgrade, when required $10k+ Service size, meter location, utility requirements and site conditions

Prices as of November 2026. Complex whole-home and design-build projects can exceed these ranges. Rebates and incentives may reduce your net project cost.

Project inquiry

Share your Tiburon project

Send the house layout, who is on the design team and what you plan to change. Drawings help but are not required to start.

  • Reviewed by a project lead, not a dispatcher
  • We tell you if your scope is not a fit for us
  • No high-pressure in-home sales appointment

Project Inquiry

Send your project details

Project type, ZIP, timeline, and how to reach you.

We design and install complete systems in the East Bay, San Francisco and Marin. We do not do repair, service calls or maintenance.

Mitsubishi Electric

Proud Mitsubishi Electric Diamond Contractor

As a Mitsubishi Electric Diamond Contractor, we design and install ducted, ductless, and multi-zone systems for Bay Area homes, with factory-trained crews and longer warranty options on qualifying residential installs.

Mitsubishi is not automatically the answer to every home. We start with what the project requires and recommend the system that makes sense.

Mitsubishi Electric H2i hyper-heat outdoor heat pump units
Mitsubishi Electric Heating and Air Conditioning Mitsubishi Electric Diamond Contractor

12 Year Parts &
Compressor Warranty

12-year warranty

Extended parts & compressor coverage on qualifying Diamond installations.

Factory-trained crews

Ongoing manufacturer training on the latest hyper-heat systems.

Priority support

Direct factory escalation if anything ever needs attention.

FAQ

Common Questions

Questions we hear from Tiburon owners about zoning, glass, hidden equipment and review.

My Tiburon house has vaulted ceilings. Where do ducts go?

Into places the architecture already offers: closets, floor cavities, soffits and low attic pockets. When none exists, ceiling cassettes or a ductless layout in those rooms avoids cutting structure. A Manual D pass tells us which approach fits.

Do I need one system or several?

Large, multi-level houses often work better as two or three zones. We compare separate ducted systems against one multi-zone outdoor unit based on each wing’s load, not a rule of thumb.

How do you size equipment for a house with so much glass?

We model window area, glazing type, orientation and shading room by room. Tiburon’s design cooling temperature is about 77°F, so the load is driven more by sun than by air temperature. That keeps equipment smaller than many owners expect.

Will the outdoor unit need design review?

It can, depending on where it goes and whether it changes the exterior. The Town requires a mechanical permit for HVAC work and separate design review may apply to some exterior items. We show unit location and screening on the plans so staff can review them together.

Which utility handles the switch?

MCE supplies generation for Tiburon by default, and PG&E delivers the power. Heat pump incentives from TECH Clean California, BayREN and utility programs change often. We confirm current availability when we quote and never assume an amount.

Can you add cooling without tearing up the house?

Often. Small-duct systems and ductless heads use narrow line sets that route through existing cavities. The tradeoff is where the indoor equipment shows. We lay that out in design before work starts.

Can a heat pump heat a big house in winter?

Yes. Tiburon’s heating design temperature is about 36°F, which is easy for modern cold-climate heat pumps. We verify capacity at that temperature in Manual S before choosing the unit.

Still have a question?

Tell us about your Tiburon project

Discuss Your Project

Project Inquiry

Ready to Talk Through Your Tiburon Project?

Tell us what you’re planning. We’ll review the project and follow up with the appropriate next step.

We design and install complete systems in the East Bay, San Francisco and Marin. We do not do repair, service calls or maintenance.

Project category
Project type
Timeline